PBM FOCUS ON EC FAN ONLY. Certificate: CE,UL,ROHS; Supply Ability: 100,000 pcs per year; MOQ: 1~100 pcs based on EXW price; 100 pcs above based on FOB price.
This 310mm dc backward curved centrifugal fan is made especially for cooling server racks and server rooms in data centers. It successfully overcomes the thermal aisle of the rack backplane and the air resistance of precision air conditioning terminals by delivering a large airflow of up to 2500 m³/h and a static pressure of 550 Pa, powered by 48V DC. This ensures uniform cooling of server clusters. With noise levels below 78 dB(A) and IP44 protection, the complete machine uses about 180W, making it appropriate for cleanroom settings. It may be coupled with environmental monitoring systems to modify airflow as necessary and supports 0–10V/PWM speed control. It is a perfect power source for liquid-cooled auxiliary air walls, in-row air conditioning, and high-density rack cooling because of its 50,000-hour lifetime, which guarantees continuous 24/7 operation in data centers.
General Characters
|
1-1 |
Rated Voltage |
48 VDC |
|
1-2 |
Operating Voltage |
36~57 VDC |
|
1-3 |
Rated Speed |
2060 RPM |
|
1-4 |
Input Current |
3.4 A |
|
1-5 |
Input Power |
163 W |
|
1-6 |
Air Flow |
1294.7 CFM / 2200 M³/H |
|
1-7 |
Static Pressure |
2.56 inH₂O / 640 Pa |
|
1-8 |
Acoustical Noise |
71 dB(A) |
|
1-9 |
Life Expectancy |
50,000 Hours (L10) At 40℃ room, humidity 15%~65%RH. |
|
1-10 |
Insulation Class |
Class B |
|
1-11 |
Motor Protection |
Locked rotor protection Polarity protection Automatic restart capability |
|
1-13 |
Speed Control |
Control input 0~10VDC / PWM |
|
1-14 |
Protection Type |
IP44 |
|
1-15 |
Signal Output |
FG (Frequency Generator) |
Mechanical Characters
|
2-1 |
Dimension |
Ø310 mm X 134.5 mm (see dimension drawing) |
|
2-2 |
Material of Impeller |
Aluminium Sheet |
|
2-3 |
Number of Blades |
6 |
|
2-4 |
Bearing System |
NMB ball bearing |
|
2-5 |
Lead Wire |
DC (AWG20 #) |
Environmental Characters
|
3-1 |
Operating Temperature |
-25℃ to 60℃ |
|
3-2 |
Storage Temperature |
-40℃ to 75℃ |
|
3-3 |
Operating Humidity |
5% to 90% RH |
|
3-4 |
Storage Humidity |
5% to 95% RH |
Performance Curve
Testing Condition:
Input Voltage----Operating voltage (48VDC)
Temperature-----Room temperature
Humidity---------65%RH
Outline Drawing
Note:
1.Connection line:DC(4×AWG20#)
2.DC: Red=Voltage Intput 48VDC, Yellow=0-10VDC/PWM, White=FG, Blue=GND;
By continuing to use the site you agree to our privacy policy Terms and Conditions.