PBM FOCUS ON EC FAN ONLY. Certificate: CE,UL,ROHS; Supply Ability: 100,000 pcs per year; MOQ: 1~100 pcs based on EXW price; 100 pcs above based on FOB price.
This duct fan is especially well-suited for long-distance duct ventilation systems because of its high static pressure of 900 Pa and big air volume of 315 m³/h. It may be put in exhaust ducts in basements, kitchens, and bathrooms in household fresh air systems to efficiently clear duct blockage and release contaminated air outside. Additionally, it is frequently utilized in industrial settings for forced cooling in machine rooms, electrical rooms, and small warehouses. The warehouse duct fan's backward-curved impeller design and high-efficiency, energy-efficient exterior rotor centrifugal construction enable direct series installation in standard DN100 ventilation ducts. High temperatures, oil mist, lengthy ducts, and plenty of bends are some of the issues with kitchen exhaust that put more strain on fans. Chinese kitchen exhaust is the target market for the 100mm EC duct fan for kitchens. It guarantees smooth fume exhaust and stops backflow even when attached to many meters of lengthy ducts, several bends, or check valves. This duct fan is an effective, dependable, and energy-efficient exhaust choice for canteen kitchens, small restaurants, and home kitchens. To keep family members from waking up, the bathroom fan runs quietly. It gets rid of moisture. Bad smells really fast. The duct fan for bathroom is great for a toilet, a hotel room, or a bathroom at home because it is quiet and does not use a lot of energy. It gives you air without making a lot of noise. The bathroom fan is very good at getting rid of moisture and bad smells from the bathroom.
General Characters
|
1-1 |
Rated Voltage |
230 VAC |
|
1-2 |
Frequency |
50/60 Hz |
|
1-3 |
Operating Voltage |
184~270 VAC |
|
1-4 |
Rated Speed |
3300 RPM |
|
1-5 |
Input Current |
0.65 A |
|
1-6 |
Input Power |
85 W |
|
1-7 |
Air Flow |
185.38 CFM 315 M³/H |
|
1-8 |
Static Pressure | 3.60 inH₂O / 900 Pa |
|
1-9 |
Acoustical Noise |
72 dB(A) |
|
1-10 |
Life Expectancy |
50,000 Hours (L10) At 40℃ room, humidity 15%~65%RH. |
|
1-11 |
Insulation Class |
Class B |
|
1-13 |
Motor Protection |
Locked rotor protection Polarity protection Automatic restart capability |
|
1-14 |
Speed Control |
Control input 0~10VDC / PWM |
|
1-15 |
Protection Type |
IP55 |
|
1-17 |
Signal Output |
FG (Frequency Generator) |
Mechanical Characters
|
2-1 |
Dimension |
286 mm X 306mm X 192mm (see dimension drawing) |
|
2-2 |
Material of Impeller |
PA66+25%GF |
|
2-3 |
Number of Blades |
7 |
|
2-4 |
Bearing System |
NMB ball bearing |
|
2-5 |
Lead Wire |
AC (AWG20#), DC (AWG22 #) |
Environmental Characters
|
3-1 |
Operating Temperature |
-25℃ to 60℃ |
|
3-2 |
Storage Temperature |
-40℃ to 75℃ |
|
3-3 |
Operating Humidity |
5% to 90% RH |
|
3-4 |
Storage Humidity |
5% to 95% RH |
Performance Curve
Testing Condition:
Input Voltage----Operating voltage (230VAC/50Hz)
Temperature-----Room temperature
Humidity---------65%RH
Outline Drawing
Note:
1.Connection line: AC(3×AWG20#),DC(4×AWG22#)
2.AC: Brown=Live Line,Blue=Null Line,Green & Yellow=Protecting Earthing;
3.DC: Red=Voltage Output +10VDC, Yellow=0-10VDC/PWM, White=FG, Blue=GND;