FOCUS ON EC FAN ONLY

400mm EC-AC Backward Curved Centrifugal Fan PB3N400B4EL 400mm EC-AC Backward Curved Centrifugal Fan PB3N400B4EL

PBM FOCUS ON EC FAN ONLY. Certificate: CE,UL,ROHS; Supply Ability: 100,000 pcs per year; MOQ: 1~100 pcs based on EXW price; 100 pcs above based on FOB price.

Share this:

400mm EC Backward Curved centrifugal fan made especially for air handling units (AHUs) in central air conditioning systems is the PB3N400B4EL. It is appropriate for crucial situations like the introduction and distribution of external fresh air in fresh air handling units and the air filtration and recirculation units in cleanroom air handling units. The unit is measured noise level of just 73 dB(A) places it in the good range of industrial centrifugal fans with the same airflow capacity. It can function steadily in cramped areas such fan section ceilings and air conditioning equipment rooms without creating a lot of disturbance.

 

General Characters

1-1

Rated Voltage

380 VAC

1-2

Frequency

50/60 Hz

1-3

Operating Voltage

304–456 VAC

1-4

Rated Speed 1580 RPM

1-5

Input Current

1.2 A

1-6

Input Power

720 W

1-7

Air Flow

3177.90 CFM / 5400 M³/H

1-8

Static Pressure

2.12 inH₂O / 530 Pa

1-9

Acoustical Noise

73 dB(A)

1-10

Life Expectancy

50,000 Hours (L10)

At 40℃ room, humidity 15%~65%RH.

1-11

Insulation Class

Class F

1-13

Motor Protection

Locked rotor protection

Polarity protection

Automatic restart capability

1-14

Speed Control

Control input 0~10VDC / PWM

1-15

Protection Type

IP44

1-17

Signal Output

FG (Frequency Generator)

 

Mechanical Characters

2-1

Dimension

Ø 400 mm X 277 mm (see dimension drawing)

2-2

Material of Impeller

Aluminium Sheet

2-3

Number of Blades

8

2-4

Bearing System

NMB ball bearing

2-5

Lead Wire

AC (AWG18 #), DC (AWG22 #)

 

Environmental Characters

3-1

Operating Temperature

-25℃ to 60℃

3-2

Storage Temperature

-40℃ to 75℃

3-3

Operating Humidity

5% to 90% RH

3-4

Storage Humidity

5% to 95% RH

Performance Curve

 

400mm EC-AC Backward Curved Centrifugal Fan PB3N400B4EL

 

Testing Condition:

Input Voltage----Operating voltage (380VAC/50Hz)

Temperature-----Room temperature

Humidity---------65%RH

 

Outline Drawing

 

400mm EC-AC Backward Curved Centrifugal Fan PB3N400B4EL

Note:

1.Connection line: AC(3×AWG18#),DC(4×AWG22#)

2.AC: Brown=L1(R),Blue=L2(S),Black=L3(T),Green & Yellow=Protecting Earthing;

3.DC: Red=Voltage Output +10VDC, Yellow=0-10VDC/PWM, White=FG, Blue=GND;

 

×