PBM FOCUS ON EC FAN ONLY. Certificate: CE,UL,ROHS; Supply Ability: 100,000 pcs per year; MOQ: 1~100 pcs based on EXW price; 100 pcs above based on FOB price.
400mm DC backward-curved centrifugal fan made especially for medical purification systems and air handling units (AHUs) is the PB3N400B24M. The brushless DC motor's low self-heating properties guarantee that the fan produces less heat when operating in cleanroom environments with consistent humidity and temperature. Because of this, very little waste heat is emitted into the airflow, preventing the AHU from experiencing an additional thermal stress. This greatly preserves exact control over the supply air temperature of the AHU while also avoiding needless energy expenditure related to adjusting for thermal interference.
PBM is an expert in the development and production of superior EC/DC fans and intelligent airflow solutions. PBM provides a broad range of customized services to satisfy the various demands of producers of commercial HVAC equipment, medical purification units, and modular air handling systems.
General Characters
|
1-1 |
Rated Voltage |
24 VDC |
|
1-2 |
Operating Voltage |
16~28 VDC |
|
1-3 |
Rated Speed |
1280 RPM |
|
1-4 |
Input Current |
3.1 A |
|
1-5 |
Input Power |
74 W |
|
1-6 |
Air Flow |
1224.08 CFM / 2080 M³/H |
|
1-7 |
Static Pressure |
1.38 inH₂O / 346 Pa |
|
1-8 |
Acoustical Noise |
60 dB(A) |
|
1-9 |
Life Expectancy |
50,000 Hours (L10) At 40℃ room, humidity 15%~65%RH. |
|
1-10 |
Insulation Class |
Class B |
|
1-11 |
Motor Protection |
Locked rotor protection Polarity protection Automatic restart capability |
|
1-13 |
Speed Control |
Control input 0~10VDC / PWM |
|
1-14 |
Protection Type |
IP44 |
|
1-15 |
Signal Output |
FG (Frequency Generator) |
Mechanical Characters
|
2-1 |
Dimension |
Ø400 mm X 134.5 mm (see dimension drawing) |
|
2-2 |
Material of Impeller |
Aluminium Sheet |
|
2-3 |
Number of Blades |
6 |
|
2-4 |
Bearing System |
NMB ball bearing |
|
2-5 |
Lead Wire |
DC (AWG20 #) |
Environmental Characters
|
3-1 |
Operating Temperature |
-25℃ to 60℃ |
|
3-2 |
Storage Temperature |
-40℃ to 75℃ |
|
3-3 |
Operating Humidity |
5% to 90% RH |
|
3-4 |
Storage Humidity |
5% to 95% RH |
Performance Curve
Testing Condition:
Input Voltage----Operating voltage (24VDC)
Temperature-----Room temperature
Humidity---------65%RH
Outline Drawing
Note:
1.Connection line:DC(4×AWG20#)
2.DC: Red=Voltage Intput 24VDC, Yellow=0-10VDC/PWM, White=FG, Blue=GND;
By continuing to use the site you agree to our privacy policy Terms and Conditions.