PBM FOCUS ON EC FAN ONLY. Certificate: CE,UL,ROHS; Supply Ability: 100,000 pcs per year; MOQ: 1~100 pcs based on EXW price; 100 pcs above based on FOB price.
120mm EC Single Inlet Blower made especially for Clean Electrical Appliances, Sweeping Robot is the PS3N120B2EM. Its dual-mode stepless speed control (0–10 VDC/PWM) allows for real-time airflow modification based on the robot vacuum's dustbin load and floor material sensors. This produces "on-demand suction," which is especially useful for robot vacuums that combine sweeping and mopping and need to run for extended periods of time. It also avoids the battery loss and needless energy waste produced by fixed-speed fans. It provides steady airflow even at high static pressure levels of 471 Pa because to its 34-blade galvanized steel forward-curved impeller and efficient volute channel design. It easily overcomes the accumulated resistance brought on by the dustbin filter, HEPA filter, airflow bends, and dust-air separation devices inside the robot vacuum system when combined with an aerodynamically optimized streamlined airflow route.
PBM is an expert in the development and production of superior EC/DC fans and intelligent airflow solutions. The robot vacuum's main control unit (MCU) can precisely monitor it thanks to its support for speed signal output (FG), which makes system integration easier. It can exactly match the cleaning system's constant airflow or constant static pressure control techniques when combined with 0–10V/PWM speed control, satisfying the dynamic suction level needs for various floor materials and filth levels. On request, we provide OEM modification services that include compatibility with acoustic foam accessories, compact size adaptations, protection rating upgrades (up to IP55), and particular wiring configurations.
General Characters
|
1-1 |
Rated Voltage |
230 VAC |
|
1-2 |
Frequency |
50/60 Hz |
|
1-3 |
Operating Voltage |
184~270 VAC |
|
1-4 |
Rated Speed | 2400 RPM |
|
1-5 |
Input Current |
0.4 A |
|
1-6 |
Input Power |
55 W |
|
1-7 |
Air Flow |
186.55 CFM / 317 M³/H |
|
1-8 |
Static Pressure |
1.88 inH₂O / 471 Pa |
|
1-9 |
Acoustical Noise |
58 dB(A) |
|
1-10 |
Life Expectancy |
50,000 Hours (L10) At 40℃ room, humidity 15%~65%RH. |
|
1-11 |
Insulation Class |
Class B |
|
1-13 |
Motor Protection |
Locked rotor protection Polarity protection Automatic restart capability |
|
1-14 |
Speed Control |
Control input 0~10VDC / PWM |
|
1-15 |
Protection Type |
IP44 |
|
1-17 |
Signal Output |
FG (Frequency Generator) |
Mechanical Characters
|
2-1 |
Dimension |
172 mm X 181 mm X 115 mm (see dimension drawing) |
|
2-2 |
Material of Impeller |
Galvanized metal shell |
|
2-3 |
Number of Blades |
38 |
|
2-4 |
Bearing System |
NMB ball bearing |
|
2-5 |
Lead Wire |
AC (AWG20#), DC (AWG22 #) |
Environmental Characters
|
3-1 |
Operating Temperature |
-25℃ to 60℃ |
|
3-2 |
Storage Temperature |
-40℃ to 75℃ |
|
3-3 |
Operating Humidity |
5% to 90% RH |
|
3-4 |
Storage Humidity |
5% to 95% RH |
Performance Curve
Testing Condition:
Input Voltage----Operating voltage (230VAC/50Hz)
Temperature-----Room temperature
Humidity---------65%RH
Outline Drawing
Note:
1.Connection line: AC(3×AWG20#),DC(4×AWG22#)
2.AC: Brown=Live Line,Blue=Null Line,Green & Yellow=Protecting Earthing;
3.DC: Red=Voltage Output +10VDC, Yellow=0-10VDC/PWM, White=FG, Blue=GND;