PBM FOCUS ON EC FAN ONLY. Certificate: CE,UL,ROHS; Supply Ability: 100,000 pcs per year; MOQ: 1~100 pcs based on EXW price; 100 pcs above based on FOB price.
300mm axial fan is primarily used in data centers and the telecommunications industry. In data centers, air-cooled cabinets, server racks, and IDC rooms often require cabinet fans for forced cooling and air circulation. This 24vdc axial fan is designed for direct installation and is compatible with DC power supplies, eliminating the need for additional voltage conversion and simplifying installation. It also provides reliable cooling for telecommunications base stations, 5G equipment cabinets, power distribution cabinets, and UPS cabinets. It is also commonly found in energy storage applications. Energy storage cabinets, photovoltaic inverters, and SVG reactive power compensation units contain high-power components that generate significant heat, requiring axial cooling fans for continuous heat dissipation. It is also used in industrial automation, such as in variable frequency drive cabinets, PLC control cabinets, and high- and low-voltage power distribution cabinets. The external rotor design offers high efficiency, low noise, and a compact footprint, making it easy to install in various cabinets without taking up excessive space.
General Characters
|
1-1 |
Rated Voltage |
24 VDC |
|
1-2 |
Operating Voltage |
16~28 VDC |
|
1-3 |
Rated Speed |
2200 RPM |
|
1-4 |
Input Current |
6.5 A |
|
1-5 |
Input Power |
156 W |
|
1-6 |
Air Flow |
1371.21 CFM / 2330 M³/H |
|
1-7 |
Static Pressure |
1.26 inH2O / 316 Pa |
|
1-8 |
Acoustical Noise |
65 dB(A) |
|
1-9 |
Life Expectance |
50,000 Hours(L10) At 40℃ room, humidity 15%~65%RH. |
|
1-10 |
Insulation Class |
Class B |
|
1-11 |
Motor Protection |
Locked rotor protection Polarity protection Automatic restart capability |
|
1-13 |
Speed Control |
Control input 0~10VDC / PWM |
|
1-14 |
Protection Type |
IP44 |
|
1-15 |
Signal Output |
FG (Frequency Generator) |
Mechanical Characters
|
2-1 |
Dimension |
Ø300 mm X 90 mm (see dimension drawing) |
|
2-2 |
Material of Impeller |
Cold rolled steel sheet |
|
2-3 |
Number of Blades |
7 |
|
2-4 |
Bearing System |
NMB ball bearing |
|
2-5 |
Lead Wire |
DC (AWG20 #) |
Environmental Characters
|
3-1 |
Operating Temperature |
-25℃ to 60℃ |
|
3-2 |
Storage Temperature |
-40℃ to 75℃ |
|
3-3 |
Operating Humidity |
5% to 90% RH |
|
3-4 |
Storage Humidity |
5% to 95% RH |
Performance Curve
Testing Condition:
Input Voltage----Operating voltage (24VDC)
Temperature-----Room temperature
Humidity---------65%RH
Outline Drawing
Note:
1.Connection line:DC(4×AWG20#)
2.DC: Red=Voltage Intput 24VDC, Yellow=0-10VDC/PWM, White=FG, Blue=GND;