PBM FOCUS ON EC FAN ONLY. Certificate: CE,UL,ROHS; Supply Ability: 100,000 pcs per year; MOQ: 1~100 pcs based on EXW price; 100 pcs above based on FOB price.
The PD3N146B2E-MZ0 209×219×270mm IP55 EC‑AC dual inlet centrifugal blower is a fully sealed, high‑efficiency fan engineered for a wide range of HVAC applications – including air conditioning, ventilation, refrigeration, and air purification – where reliable performance under demanding conditions is essential. Operating at 230V AC rated voltage, 1850 RPM, delivering an impressive 1300 m³/h high‑capacity airflow and 850 Pa high static pressure, this IP55 rated dual inlet blower for HVAC systems and high airflow double inlet fan for air purification ensures consistent, energy‑saving operation even in the most challenging central system configurations.
With a full IP55 protection rating – completely dust‑tight and resistant to sustained low‑pressure water jets – and a high‑strength cold‑rolled steel impeller, this heavy‑duty dual inlet centrifugal fan for equipment rooms delivers long‑term stability in demanding environments such as air conditioning plant rooms and mechanical equipment spaces. PBM's OEM customization services cover multiple dimensions – including custom lead wire configurations, upgraded ingress protection (IP) ratings, corrosion‑resistant surface treatments, and optional silencer/filter box accessories – tailored specifically for HVAC systems, ventilation and purification equipment, and other specialized applications. Whether you need a 1300 m³/h dual inlet blower for commercial air conditioning, a corrosion‑treated fan for refrigeration systems, or a silencer‑equipped centrifugal blower for quiet building ventilation, PBM delivers precision‑engineered solutions with full engineering support from prototype to production.
General Characters
|
1-1 |
Rated Voltage |
230 VAC |
|
1-2 |
Frequency |
50/60 Hz |
|
1-3 |
Operating Voltage |
184~270 VAC |
|
1-4 |
Rated Speed | 1850 RPM |
|
1-5 |
Input Current |
1.55 A |
|
1-6 |
Input Power |
220 W |
|
1-7 |
Air Flow |
765.05 CFM / 1300 M³/H |
|
1-8 |
Static Pressure |
3.40 inH2O / 850 Pa |
|
1-9 |
Acoustical Noise |
72 dB(A) |
|
1-10 |
Life Expectance |
50,000 Hours(L10) At 40℃ room, humidity 15%~65%RH. |
|
1-11 |
Insulation Class |
Class B |
|
1-13 |
Motor Protection |
Locked rotor protection Polarity protection Automatic restart capability |
|
1-14 |
Speed Control |
Control input 0~10VDC / PWM |
|
1-15 |
Protection Type |
IP55 |
|
1-17 |
Signal Output |
FG (Frequency Generator) |
Mechanical Characters
|
2-1 |
Dimension |
209 mm X 219 mm X 270 mm (see dimension drawing) |
|
2-2 |
Material of Impeller |
Cold rolled steel sheet |
|
2-3 |
Number of Blades |
38 |
|
2-4 |
Bearing System |
NMB ball bearing |
|
2-5 |
Lead Wire |
AC (AWG20#),DC (AWG24#) |
Environmental Characters
|
3-1 |
Operating Temperature |
-25℃ to 60℃ |
|
3-2 |
Storage Temperature |
-40℃ to 75℃ |
|
3-3 |
Operating Humidity |
5% to 90% RH |
|
3-4 |
Storage Humidity |
5% to 95% RH |
Performance Curve
Testing Condition:
Input Voltage----Operating voltage (230VAC/50Hz)
Temperature-----Room temperature
Humidity---------65%RH
Outline Drawing
Note:
1.Connection line: AC(3×AWG20#),DC(4×AWG24#)
2.AC: Brown=Live Line,Blue=Null Line,Green & Yellow=Protecting Earthing;
3.DC: Red=Voltage Output +10VDC, Yellow=0-10VDC/PWM, White=FG, Blue=GND;