PBM FOCUS ON EC FAN ONLY. Certificate: CE,UL,ROHS; Supply Ability: 100,000 pcs per year; MOQ: 1~100 pcs based on EXW price; 100 pcs above based on FOB price.
The PB3N220B48-TZ0 220mm IP55 DC Backward Curved Centrifugal Fan is designed for cleanroom systems and FFU fan filter units in semiconductor cleanrooms, pharmaceutical workshops, and biological laboratories — overcoming HEPA filter resistance and maintaining stable cleanroom differential pressure in ultra-high static pressure industrial ventilation applications.
Rated at 48V DC and powered by advanced brushless DC (BLDC) / EC motor technology, this backward curved centrifugal fan delivers an industry-leading 1165 m³/h (685.6 CFM) of airflow and 950 Pa (3.80 inH2O) of ultra-high static pressure at 3,500 RPM. The 950 Pa ultra-high static pressure easily overcomes cumulative resistance from HEPA filters, dense coil arrays, and long-distance ductwork, ensuring stable airflow in AHU, FFU, and cleanroom systems.
Choose the PB3N220B48-TZ0 for a high static pressure, low noise, IP55 EC-DC backward curved centrifugal fan for your most demanding cleanroom and FFU applications.
General Characters
|
1-1 |
Rated Voltage |
48 VDC |
|
1-2 |
Operating Voltage |
36~57 VDC |
|
1-3 |
Rated Speed |
3500 RPM |
|
1-4 |
Input Current |
3.8 A |
|
1-5 |
Input Power |
182.4 W |
|
1-6 |
Air Flow |
685.6 CFM / 1165 M³/H |
|
1-7 |
Static Pressure |
3.80 inH2O / 950 Pa |
|
1-8 |
Acoustical Noise |
72 dB(A) |
|
1-9 |
Life Expectance |
50,000 Hours(L10) At 40℃ room, humidity 15%~65%RH. |
|
1-10 |
Insulation Class |
Class B |
|
1-11 |
Motor Protection |
Locked rotor protection Polarity protection Automatic restart capability |
|
1-13 |
Speed Control |
Control input 0~10VDC / PWM |
|
1-14 |
Protection Type |
IP55 |
|
1-15 |
Signal Output |
FG (Frequency Generator) |
Mechanical Characters
|
2-1 |
Dimension |
Ø220 mm X 90 mm (see dimension drawing) |
|
2-2 |
Material of Impeller |
PA66+GF |
|
2-3 |
Number of Blades |
7 |
|
2-4 |
Bearing System |
NMB ball bearing |
|
2-5 |
Lead Wire |
Red, Blue(AWG18#);Yellow, White(AWG24#)
|
Environmental Characters
|
3-1 |
Operating Temperature |
-25℃ to 60℃ |
|
3-2 |
Storage Temperature |
-40℃ to 75℃ |
|
3-3 |
Operating Humidity |
5% to 90% RH |
|
3-4 |
Storage Humidity |
5% to 95% RH |
Performance Curve
Testing Condition:
Input Voltage----Operating voltage (48VDC)
Temperature-----Room temperature
Humidity---------65%RH
Outline Drawing
Note:
1.Connection line: Red, Blue(AWG18#);Yellow, White(AWG24#)
2.DC: Red=Voltage Intput 48VDC, Yellow=0-10VDC/PWM, White=FG, Blue=GND;