Fan units, HVAC systems, data centers, and air conditioning and heat pump systems are the main applications for our axial fans. Before each product leaves the plant, we constantly make sure it passes many stringent quality testing. Dynamic and static balancing are included in thorough performance testing to guarantee seamless functioning. Every fan must go through our testing facilities, which include electromagnetic vibration test benches, EMC testing systems, vibration and noise test chambers, and endurance test chambers, before being sent. Superior quality, in our opinion, can withstand any examination. Applications for our axial fan blower include fan wall unit, building ventilation systems, FFU filter units (FFU fans), cleanroom equipment, and precision air conditioning. The fundamental idea behind our products is high efficiency, energy savings, and a constant flow of fresh air.
Our business specializes in the development and production of fans and motors, offering solutions for ventilation and cooling systems (axial cooling fan)across the world.Industrial axial fan can be customized in addition to conventional products to satisfy particular customer needs.
General Characters
|
1-1 |
Rated Voltage |
380 VAC |
|
1-2 |
Frequency |
50/60 Hz |
|
1-3 |
Operating Voltage |
304~456 VAC |
|
1-4 |
Rated Speed |
1690 RPM |
|
1-5 |
Input Current |
1.5 A |
|
1-6 |
Input Power |
850 W |
|
1-7 |
Air Flow |
5667.26 CFM / 9630 M³/H |
|
1-8 |
Static Pressure |
2.20 inH2O / 550 Pa |
|
1-9 |
Acoustical Noise |
78 dB(A) |
|
1-10 |
Life Expectance |
50,000 Hours(L10) At 40℃ room, humidity 15%~65%RH. |
|
1-11 |
Insulation Class |
Class F |
|
1-13 |
Motor Protection |
Locked rotor protection Polarity protection Automatic restart capability |
|
1-14 |
Speed Control |
Control input 0~10VDC / PWM |
|
1-15 |
Protection Type |
IP44 |
|
1-17 |
Signal Output |
FG (Frequency Generator) |
Mechanical Characters
|
2-1 |
Dimension |
Ø500 mm X 182 mm (see dimension drawing) |
|
2-2 |
Material of Impeller |
Cool rolled steel sheet |
|
2-3 |
Number of Blades |
5 |
|
2-4 |
Bearing System |
NMB ball bearing |
|
2-5 |
Lead Wire |
AC (AWG18#),DC (AWG22 #) |
Environmental Characters
|
3-1 |
Operating Temperature |
-25℃ to 60℃ |
|
3-2 |
Storage Temperature |
-40℃ to 75℃ |
|
3-3 |
Operating Humidity |
5% to 90% RH |
|
3-4 |
Storage Humidity |
5% to 95% RH |
Performance Curve
Testing Condition:
Input Voltage----Operating voltage (380VAC/50Hz)
Temperature-----Room temperature
Humidity---------65%RH
Outline Drawing
Note:
1.Connection line: AC(3×AWG18#),DC(4×AWG22#)
2.AC: Brown=L1(R),Blue=L2(S),Black=L3(T),Green & Yellow=Protecting Earthing;
3.DC: Red=Voltage Output +10VDC, Yellow=0-10VDC/PWM, White=FG, Blue=GND;