FOCUS ON EC FAN ONLY

133mm EC-DC Single Inlet Blower

133mm EC-DC Single Inlet Blower

Please feel free to contact us
280mm EC-AC Single Inlet Blower

280mm EC-AC Single Inlet Blower

Please feel free to contact us
100mm EC-DC Single Inlet Blower

100mm EC-DC Single Inlet Blower

Please feel free to contact us
097mm EC-DC Single Inlet Blower

097mm EC-DC Single Inlet Blower

Please feel free to contact us

Blowers, Single Inlet, Technical Features Overview

Higher Air Pressure and Sturdy Anti-vibration Housing

PBM blowers, with forward curved impeller, compact EC motor drives optimized single inlet scroll housing. 

The fans could be installed at any directions with fixed riveting nut at scroll housing metal ring, optimized radial scroll housing design and plastic, metal sheet optional impeller to output higher air pressure at customer requested working point in their ventilation duct system or unit box of different materials, such as galvanized metal, aluminum, copper, PE, PVC, polyfoam etc.

AC and DC power supply are available for entire range of fans with integrated and intelligence EC technology motor with inside or outside mounted international standard remote control R485 communication protocol that’s suitable to be adopted in IoE(Internet of Everything), IoT(Internet of Things), smart home system, Industry 4.0 and committed to Carbon Neutrality climate change by reducing customers carbon footprints. 

PFC(Power Factor Correction), up to λ>96%, is optional for electricity grad stabilization compliance in certain circumstances of applications. ErP2015 (Energy-related Products) Directive conformity, COMMISSION REGULATION (EU) No 327/2011 of 30 March 2011 implementing Directive 2009/125/EC of the European Parliament and of the Council with regard to eco-design requirements for fans driven by motors with an electric input power between 125 W and 500 kW.

Single Inlet Blower

Impeller Sizes: From 120mm to 280mm diameter;

Sound Level: From 50dBA to maximum 79dBA according different rotation speed;

Airflow: Maximum to 3,000CMH, Cubic Meter per Hour, equal to approx. 1,766CFM , Cubic Feet per Minute;

Air Pressure: Maxim to 900Pa, equal to 91.84mm H2O and to 3.62 inches H2O;

Power: Maximum motor input power goes to 950W (equal to 1.29hp, horsepower) at motor diameter 138mm.

DC Blower Single Inlet D(133-280)

DC Blower Single Inlet D(133-280)

EC Blower Single Inlet D(120-200)

EC Blower Single Inlet D(120-200)

Application

Dehumidifier

Dehumidifier
Powerful airflow circulation for dehumidifiers. High static pressure, low noise, moisture-resistant, improving efficiency and ensuring compressor stability.

Ovens and Cooktops

Ovens-and-Cooktops
Heat-resistant cooling for ovens and cooktops. Anti-thermal radiation, low noise, long-life, ensuring stable temperature control and cooking safety.

Vertical HVAC Independent

Vertical-HVAC-Independent-System
Heat-resistant cooling for ovens and cooktops. Anti-thermal radiation, low noise, long-life, ensuring stable temperature control and cooking safety.

Parameter summary table

Please click on the model in the corresponding table to go to the product details page.

DOWNLOAD

Model Rated Voltage Rated Power Rated Speed Air Flow Air Pressure EC/DC/AC Inquire
PS3N097B24M 24 VDC 76.8 W 3650 RPM 210 M³/H 740 Pa DC Inquire
PS3N097B48M 48 VDC 76.8 W 3650 RPM 210 M³/H 740 Pa DC Inquire
PS3N100B24M 24 VDC 24 W 2800 RPM 113.4 M³/H 338 Pa DC Inquire
PS3N100B48M 48 VDC 24 W 2800 RPM 113.4 M³/H 338 Pa DC Inquire
PS3N120B2EM 230 VAC 55 W 2400 RPM 317 M³/H 471 Pa EC Inquire
PS3N120B24M 24 VDC 72 W 2800 RPM 317 M³/H 471 Pa DC Inquire
PS3N120B48M 48 VDC 72 W 2800 RPM 317 M³/H 471 Pa DC Inquire
PS3N133B24M 24 VDC 60 W 2200 RPM 238 M³/H 525 Pa DC Inquire
PS3N133B48M 48 VDC 60 W 2200 RPM 238 M³/H 525 Pa DC Inquire
PS3N140B2EM 230 VAC 170 W 2600 RPM 567.7 M³/H 696 Pa EC Inquire
PS3N140B24M 24 VDC 80 W 1800 RPM 450 M³/H 420 Pa DC Inquire
PS3N140B48M 48 VDC 80 W 1800 RPM 450 M³/H 420 Pa DC Inquire
PS3N150B24M 24 VDC 105 W 2400 RPM 500 M³/H 750 Pa DC Inquire
PS3N150B48M 48 VDC 105 W 2400 RPM 500 M³/H 750 Pa DC Inquire
PS3N160B2EM 230 VAC 170 W 1950 RPM 688 M³/H 810 Pa EC Inquire
PS3N160B24M 24 VDC 105 W 1950 RPM 550 M³/H 620 Pa DC Inquire
PS3N160B48M 48 VDC 105 W 1950 RPM 550 M³/H 620 Pa DC Inquire
PS3N180B2EM 230 VAC 170 W 1500 RPM 820 M³/H 900 Pa EC Inquire
PS3N180B24M 24 VDC 90 W 1250 RPM 600 M³/H 600 Pa DC Inquire
PS3N180B48M 48 VDC 90 W 1250 RPM 600 M³/H 600 Pa DC Inquire
PS3N200B2EM 230 VAC 220 W 1600 RPM 792 M³/H 708 Pa EC Inquire
PS3N225B2EM 230 VAC 230 W 1090 RPM 1360 M³/H 620 Pa EC Inquire
PS3N250B2EM 230 VAC 230 W 840 RPM 1710 M³/H 580 Pa EC Inquire
PS3N280B4EM 380 VAC 950 W 1150 RPM 3000 M³/H 650 Pa EC Inquire
load more

FAQ

  • How do I choose the right single inlet blower?

    +
    When selecting a single inlet blower, important factors include:
    • Required airflow (CFM or m³/h)
    • Static pressure requirements
    • Installation space
    • Voltage and frequency
    • Noise limitations
    • Motor type (AC or EC motor)
    • Operating environment
    • Energy efficiency requirements
    Reviewing the blower performance curve is important to ensure proper system matching.
  • What are the advantages of a single inlet blower?

    +
    Single inlet blowers offer several advantages, including:
    • Compact structure
    • Stable airflow performance
    • Easier installation and maintenance
    • Lower system complexity
    • Reliable static pressure capability
    • Good integration flexibility for OEM equipment
    These features make them widely used in commercial and industrial ventilation systems.
  • Can single inlet blowers be customized?

    +
    Yes. Many manufacturers offer customized single inlet blower solutions for OEM and industrial projects. Customization options may include:
    • Airflow and pressure specifications
    • AC or EC motor configuration
    • Voltage and frequency
    • Speed control systems
    • Mounting structure
    • Corrosion-resistant materials
    • Noise reduction optimization
    • Special housing or impeller designs
    Customized blowers are widely used in industrial equipment and specialized ventilation systems.
  • Where are single inlet blowers commonly used?

    +
    Single inlet blowers are widely used in:
    • HVAC systems
    • Air handling units (AHU)
    • Industrial ventilation equipment
    • Air purification systems
    • Electronic equipment cooling
    • Commercial kitchen ventilation
    • Machinery cooling systems
    • Agricultural ventilation
    Their compact design makes them suitable for applications with limited installation space.
  • What is the difference between a single inlet blower and a dual inlet blower?

    +
    The main difference is the air intake structure. A single inlet blower draws air from one side of the impeller, while a dual inlet blower draws air from both sides. Single inlet blowers are typically preferred for:
    • Compact equipment designs
    • Moderate airflow requirements
    • Simpler duct connections
    • Industrial machinery cooling
    • Space-limited installations
    Dual inlet blowers are more suitable for higher airflow applications such as large HVAC systems.

We are here to help